Power Outages Cause Long-Term Damage To Your Equipment And Your Business


The main damage caused by a power outage is obvious. If commercial power fails at your remote site, and you don't have a backup power supply, the site will go dark. Dark sites mean network downtime, lost revenue, and angry customers who will shift their business to another provider.

But power outages also cause long-term damage that isn't so obvious. A complete power loss at a remote site can affect your gear - and your business - even after power is restored. Read more here

Do You Know These Eight Startling Network Outage Statistics?

Power outages damage more than you think - including your bottom line.
Power outages damage more than you think - including your bottom line.

Here are some of the top hidden damages caused by power outages. Consider these 5 good reasons why you need a bulletproof power monitoring and power backup plan (see a real-life case study here).

1. Thermal Shutdown from Failed Air Conditioning.

You may have backup power for your revenue-generating gear, but do you have backup power for your air conditioning?

A surprising number of telecoms forget about the need for air conditioning in a power outage. They may have a DC battery power plant for revenue-generating gear, but they provide no alternate AC power for air conditioning. Just because gear isn't rack-mounted doesn'tmean it's not vital to network operations.

The revenue-generating equipment keeps running - until the rising temperature forces a thermal shutdown. Thermal shutdown from failed air conditioning is, in the long run, a greater expense than a site that simply fails from a power outage. Equipment in thermal shutdown can't be restarted until the temperature returns to normal - long after the power outage is over. This makes recovery time longer and reduces revenue.

2. Battery Damage.

Most backup batteries are not designed to be completely drained of electricity. For the long-term working life of the battery, it must be joined to a constant source of recharging power, either commercial or from a working generator.

Batteries that are run all the way down can damaged permanently. Considering the expense of telecom-quality batteries, multiplied by the number of remote sites affected by the outage, this can become a noticeable business expense.

Heat stemming from failed air conditioning will dramatically shorten the useful life of batteries. For example, a lead-acid battery that would last ten years under ordinary conditions will be reduced to only 1 1/4 years if it is consistently operated at temperatures above 122 degrees Fahrenheit.

3. Increased Windshield Time and Added Truck Rolls.

Anytime you have to put a highly paid technician in a truck and send him to a remote site you are losing money. If the problem could have been handled through monitoring and control relays, you're losing money.

Your power loss recovery plan must include an adequate source of backup power, and a means of switching to backup power automatically. You must also be able to monitor the status of your backup power supply, and regularly test whether battery levels are adequate and backup generators are functional.

Unmonitored batteries (Click here to learn more about battery voltage monitoring) cause excessive truck rolls, and your likely have more unmonitored batteries than you realize. For example, start-up batteries for generators are typically not monitored. If commercial power fails, and the generator can't start because of a drained starter battery, you'll definitely have to send a maintenance technician. If the battery is unmonitored, you won't know it until you need it. Another way to prevent this is to regularly exercise your backup generators.

(T/MonXM can help keep your power supply in good order. T/MonXM's derived alarms feature makes it easy to schedule generator self-tests that happen entirely in the background. You receive an alarm only if the generator test is not performed. For more information, see "Creating Derived Alarms for Events That Don't Happen.")

Maintaining your backup power supply will reduce the damage caused by power outages and the need for repairs, keeping your windshield time and truck rolls to the bare minimum.

4. Loss of Remote Visibility.

Your remote monitoring gear also needs a reliable source of backup power. A major service breakdown is no time to lose visibility of your remote sites.

If your remote monitoring gear is offline during a power outage, you'll miss these vital alarms:

  1. Status of backup power supply.
  2. Environmental alarms for overheating, fire, and water damage.
  3. Site security, door, gate, and intrusion alarms.
5. Lost Revenue Plus Repair, Replacement, and Manpower Costs.

What all these hidden damages add up to is unnecessary costs. The effects of a power outage are not only on your gear, or on your actions - the true net effect is on your bottom line.

The financial effect of a power outage falls into four categories:

  1. Lost revenue.
  2. Repair of damaged gear.
  3. Replacement of gear damaged beyond repair.
  4. Manpower costs of restoring service.

Unless you have an adequate backup plan, power outages mean increased costs and lost revenue. You owe it to your business to protect yourself with a proactive response to power outages.

Click Here to Learn More about UPS Battery Backup Monitoring.

Sitemap