Preface
February 7, 2006
T/MonXM 4.7 User Manual
IAM-5 and T/MonXM Workstation Port Interface Cartridges
Intelligent Controller Card
The Intelligent Controller Cards are switch addressable for 4
sequential ports at a time. The T/MonXM WorkStation will accept
up to 4 cards (limit of 16 ports).
D-PC-600-10A-00 Intelligent Controller Card
Four (4) Port Intelligent Controller Card for Ports 1-16 with RS232
Interface.
D-PC-602-10A-00 Intelligent Controller Card
Four (4) Port Intelligent Controller Card for Ports 1-16. Interfaces
available with the factory installation of up to four docking mod-
ules. Depending on interface requirements, the 602 Card can be
equipped with a variety of modules. The 602 Card docking modules
are described below.
D-PC-603-10A-00 Intelligent Controller Card for Pentium
T/MONs
Shorter version of the 602 for use in the short slots of TMON
Pentium mother boards. Uses one docking module and three hard-
wired RS232 or RS422/485 ports.
Docking Modules
D-PR-140-10A-00 212 Type 1200 Baud Internal Modem
Provides 212 type 1200 baud modem interface for the 602 card.
D-PR-145-10A-00 212 Type 2400 Baud Internal Modem
Provides 212 type 2400 baud modem interface for the 602 card.
D-PC-635-10A-00 202 Type 1200 Baud Internal 4-Wire Modem
Provides 202 Tone Modem interface for the 602 card.
D-PC-645-10A-00 RS232 Docking Module
Provides RS232 interface for the 602 card.
D-PC-655-10A-00 RS422/RS485 Docking Module
Provides RS422/RS485 interface for the 602 card.
In addition to the 602 card described above, versions are available
which have the equivalent of the docking modules hard-wired to the
card. See the DPS Catalog, or call us at (800) 622-3314 for details.
Uninterruptible Power System (UPS)
The Uninterruptible Power System (UPS) is line-interactive and
computer-grade quality. It has outstanding lightning and brownout
protection, and RF noise filtering. Because the software is commu-
nicating with the UPS, there is no break in power transfer between
line power and UPS usage. The UPS has two operational modes:
time-out and extended operation. Time-out mode allows a user
assignable amount of time, in minutes, after going to battery power
before T/MonXM will be shut down. This allows performance of an
orderly shutdown without corrupting alarm data files. Extended
operation mode allows T/MonXM to continue normal operation
until two minutes of battery operation remain before the it will be
shut down. In the event of an extended overnight power failure this
Fig. 1.7 - Intelligent
Controller Card
Fig. 1.8 - Docking module